Model
: FCO730 |
|
|
Àú°¡Çü standard air ¡¤ gas Leak Detector FCO 730Àº RS232 ¶Ç´Â Isolated RS485 port·Î host PC¸¦ ÅëÇÏ¿© data ÄÁÆ®·ÑÀ» ±âº»À¸·Î ÇÏ´Â ´©¼³ °ËÁö ½Ã½ºÅÛÀ¸·Î ÀûÇÕÇÏ´Ù.
¡¤ Æ®·£½ºÁöÅÍ ÀÔÃâ·ÂÀ» ÅëÇÑ PLC°â¿ë ¡¤ Rack mountain ºÎÂø°¡´É (¿É¼Ç) ¡¤ 8°³±îÁö ½ÃÇè °¡´ÉÇÑ Multi-Test Version(¿É¼Ç) |
|
|
|
|
|
|
|
. No. of TESTS : Standard single test with optinal 8 test simple sequence with advanced input and output options
. Accuracy : 1% FSD, ¡¾1 digit
. Zero adjustment : automatic for leak, semi-automatic for pressure
. Resolution : Display 1:2000
. Repeatability : <1% FSD
. Electrical connectons : 9 pin D(RS232), multi-way detachable screw terminal(options), multi-way detachable screw terminal (inputs), multi-way detachable screw terminal(power)
. Supply voltage : 24V dc ¡¾10%
. Supply power : <500mA
. Timers : 0,01s to 999s
. Air supply : Clean, dry air
. Supply pressure : Max. 16 bar Gauge, Min. 5 bar gauge.
. Overall dimensions - Bench case : 294 x 232 x 145mm
. Pneumatic connections : Supply 6 mm push in, Exhaust pilot 4 mm push in, Test/reference 1/8" BSPF |
|
|