Pressure Measurement System / Flowmeters
>> PRODUCT MAKER :    
 
Model : FCO96
 
Low Pressure Laminar Flow Elements
FCO96 ½Ã¸®Áî´Â 0.1ml/min~10000l/minÀÇ low volume air¿Í gas flowÀÇ ÃøÁ¤À» À§ÇÑ À¯·® ÃøÁ¤ ÀåÄ¡ÀÌ´Ù.

Àû¿ë : Core porosity testing
          Vacuum cleaner testing
          Injector testing 
          Airline metering
          Gas burner setting
          Respiration monitoring
          Catalytic converter testing
          Air filtration control
     
 
 
MODEL / RANGE / NOMINAL DP
FCO96-20 C / 0 TO 20 ML/MIN / 5 TO 10 MMH2O
FCO96-200 C / 0 TO 200 ML/MIN / 5 TO 10 MMH2O
FCO96-2 L / 0 TO 2 L/MIN / 5 TO 10 MMH2O
FCO96-5 L / 0 TO 5 L/MIN / 5 TO 10 MMH2O
FCO96-20 L / 0 TO 20 L/MIN / 5 TO 10 MMH2O
FCO96-30 L / 0 TO 30 L/MIN / 5 TO 10 MMH2O
FCO96-200 L / 0 TO 200 L/MIN / 5 TO 10 MMH2O
FCO96-2000 L / 0 TO 2,000 L/MIN / 5 TO 10 MMH2O
FCO96-10000 L / 0 TO 10,000 L/MIN / 5 TO 10 MMH2O

* Specification
. PRINCIPLE : VOLUME FLOW PRIMARY FLOWELEMENTS USING LAMINAR FLOWBASED ON REYNOLDS NUMBERSBELOW 500
. RESOLUTION : ACCORDING TO DP INSTRUMENT USED
. ACCURACY : <¡¾1% READING
. STATIC PRESSURE : 0 TO 7 BAR G
. TRANSDUCERS & READINGS : USE FURNESS CONTROLS¡¯ LOW-RANGE DIFFERENTIAL PRESSURE TRANSDUCERS,TRANSMITTERS AND INDICATORS,RESOLUTION AROUND 1:2000
. GAS TYPES : ANY DRY CLEAN NON-CORROSIVE GAS
. MATERIAL OF CONSTRUCTION : ALUMINIUM, BRASS, EPOXY RESINSAND STEEL ON FCO96-2000 L