Gas Monitoring System / Sampling System
>> PRODUCT MAKER :    
 
Model : SGS01
 
¡Ü Single point sampling system
¡Ü µ¿½Ã¿¡ ¼¼°¡Áö °¡½º °ËÁö °¡´É
¡Ü Full flow monitoring
¡Ü ¼³Ä¡°¡ ¸Å¿ì °£Æí
¡Ü °¡½º°¡ Áö³ª°¡´Â °÷Àº ¸ðµÎ PTFE ¶Ç´Â PVDF ÀçÁú·Î Á¦ÀÛµÊ
     
 
 
. Sample lines : 10mm od, 8mm id, reinforced nylon, polypropylene or HDPE(non-reactive gases), PTFE or PVDF(reactive gases), installed in plastic or metallic conduit for physical protection.
. Max. line length : Up to 1km
. Exhaust : 6mm od comopression fitting
. Drain : 10mm od compression fitting
. Sample flow rate : 2~5 litre/min(typical)
. Flashback arrestores : 90µ, 1.6mm thick, 303 stainless steel
. Overall dimensions : 600 x 800 x 300mm
. Weight : 30kg
. Operating temp. : 1- to 25¡É
. Power : 110 or 220/240 V ac, 50/60Hz
. Inputs : 4 to 20mA 2 or 3 wire
. Outputs : Common and individual low and high alarm relays, common fault relays, SPCO contacts rated 5A at 250V, non-inductive load.
Individual 4 to 20mA outputs, maximum load 700 ohms