Model
: PGS32 |
|
|
¡Ü Programmable gas sampling system ¡Ü PC·Î system configuration anc control ¡Ü ÇϳªÀÇ Ä³ºñ³ÝÀ¸·Î 32°³ÀÇ sample points¸¦ ÀÚµ¿À¸·Î ¸ð´ÏÅ͸µ ¡Ü Pellistor, Electrochemical, Thermal conductivity, Semiconductor ¶Ç´Â Infrared Detector ¸¦ ¼¾¼ Á¾·ù¿¡ »ó°ü¾øÀÌ 8°³±îÁö ¿¬°á °¡´É ¡Ü Automatic data logging |
|
|
|
|
|
|
|
* Sampling System . Sample lines : 10mm od, 8mm id, reinforced nylon, polypropylene or HDPE(PTFE or PVDF for reactive gases), installed in plastic or metallic conduit for physical protection.
. Max. line length : Up to 1km
. Exhausts : 6mm od compression fitting
. Drains : 10mm od compression fitting
. Flashback arrestores : 90µ, 1.6mm thick, 303 stainless steel
* Cabinet . Overall dimensions : Top cabinet ; 380 x 600 x 350 mm ; Bottom cabinet ; 760 x 600 x 350 mm
. Weigt : 70kg
. Temperature range : 10 to 25¡É
* Electrical . Power : 110 or 230V ac 50/60Hz
. Inputs/Outputs : Any combination of relay and analogue modules, up to a maximum of 4 modules. Relay modules contain 8 output relays - 4 x SPCO 10A and 4 x DPCO 5A. All contacts rated at 250V, non-inductive load. Analogue modules contain 8 inputs and 2 outputs, all 4-20mA, rated 800 ohms max. load at 24V dc.
|
|
|