Gas Monitoring System / Portable Gas Detectors
>> PRODUCT MAKER :    
 
Model : New Gasman
 
¡Ü ÈÞ´ë¿ëÀ¸·Î ÇÑ°¡Áö °¡½º °ËÁö
¡Ü »ê¼Ò ¹× µ¶¼º, Æø¹ß¼º °¡½º °ËÁö
¡Ü ¹öÆ° Çϳª·Î °£´ÜÈ÷ ÀÛµ¿
¡Ü ÃøÁ¤°¡½º : Flammable, Oxygen, H2S, CO, SO2, CL2, NO2, NH3, HCL µî
¡Ü À§Çè ºÐÀ§±â¿¡¼­ °æº¸µî ¹× °æº¸À½/Áøµ¿ ±â´É
¡Ü µ¶¼º °¡½ºÀÇ °æ¿ì TWA ¾Ë¶÷ ±â´É
¡Ü °ß°íÇÑ Polycarbonate housing
¡Ü º»Áú ¾ÈÀü ¹æÆøÇüÀ¸·Î¼­ À§Çè Áö¿ª »ç¿ë °¡´É
     
 
 
Measurement : 0 ~ 100%LEL Flammable gas
0 to 25% Oxygen
H2S, CO, SO2, CL2, NO2, NH3, O3, H2, HCN, HCL, HF, Phosphine, Ethylen oxide,
COCL2, CLO2, NO, F2,

Display : Custom LCD with backlight, with display of gas concentration.

Response time : Flammable 20s, Toxic 20s, Oxygen 10s

Audible alarms : 95dBA

Visible alarms : Dual colour red/blue flashing LEDs in gas hazard

Vibrating alarms : Internal vibrating alarm

Datalogging : Full timed datalogging with adjustable sample rate.

Operating temp. : -20 to +55¡É

Humidity : 0 ~99% RH non condensing

Weight : 130g flammable
100g Oxygen
90g toxic

Dimensions : 90 x 48 x 24 mm

Approvals : EEx ia(d) IIC T4 (Toxic/Oxygen)
EEx iad IIC T4 (Flammable)

Ingress protection : IP66/67

PC interface : RS232 connection from interface module in charger
RS232/USB convertor available

Battery types : Rechargable Li-ion battery
Non rechargeable Lithium cell